DYNATRON/BONDO CORPORATION -- 428 FIBERGLASS PANEL ADHESIVE -- 8040-00N019641
===================== Product Identification =====================
Product ID:428 FIBERGLASS PANEL ADHESIVE
MSDS Date:06/04/1988
FSC:8040
NIIN:00N019641
=== Responsible Party ===
Company Name:DYNATRON/BONDO CORPORATION
Address:3700 ATLANTA INDUSTRIAL PARKWAY NW
City:ATLANTA
State:GA
ZIP:30331-1098
Country:US
Info Phone Num:800-241-3386
Emergency Phone Num:404-696-2730 OR 404-971-1502
Preparer's Name:S ABDUL RAZZAK
CAGE:16522
=== Contractor Identification ===
Company Name:BONDO/MAR-HYDE CORP
Address:3700 ATLANTA INDUSTRIAL PKWY NW
Box:City:ATLANTA
State:GA
ZIP:30331
Country:US
Phone:404-696-2730
CAGE:16522
============= Composition/Information on Ingredients =============
Ingred Name:UNSATURATED POLYESTER RESINS
CAS:26123-45-5
Fraction by Wt: >50%
Ingred Name:STYRENE, MONOMER (SARA III)
CAS:100-42-5
RTECS #:WL3675000
Fraction by Wt: <20%
OSHA PEL:100 PPM
ACGIH TLV:S,50PPM/100STEL;9293
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:TALC (CONTAINING NO ASBESTOS)
CAS:14807-96-6
RTECS #:WW2710000
Fraction by Wt: <50%
OSHA PEL:2 MG/M3 RDUST
ACGIH TLV:2 MG/M3 RDUST; 9192
Ingred Name:FIBROUS GLASS
CAS:65997-17-3
OSHA PEL:15 MG/M3 (MFR)
ACGIH TLV:10 MG/M3 (MFR)
Ingred Name:MUSCOVITE;(SILICEOUS MICA)
CAS:1318-94-1
OSHA PEL:3 MG/M3 RDUST
ACGIH TLV:3 MG/M3 RDUST
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYE AND UPPER RESPIRATORY
IRRITATION FROM VAPOR INHALATION. MINOR SKIN IRRITATION FROM
CONTACT WITH MATERIAL. CHRONIC:MAY FEEL DRUGGED, BECOME SLEEPY OR
UNCONSCIOUS. REPEATED SKIN CONTACT MAY CA USE RASH, WITH PROLONGED
EXPOSURE POSSIBLE DEVELOPING TO DERMATITIS. IF ECZEMATOUS DEVELOPS,
THIS (EFTS OF OVEREXPOSURE)
Explanation of Carcinogenicity:STYRENE:CLASS 2B (IARC).
Effects of Overexposure:HLTH HAZ:MOST OFTEN OCCURS ON THE BACK OF
HANDS, WRISTS AND FOREARMS.
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH CHRONIC
RESPIRATORY CONDITIONS (I.E., ASTHMA, CHRONIC BRONCHITIS,
EMPHYSEMA, ETC.) MAY BE ADVERSELY AFFECTED BY ANY FUME OR AIRBORNE
PARTICULATE MATTER EXPOSURE.
======================= First Aid Measures =======================
First Aid:EYE:FLUSH WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15
MINUTES, LIFTING UPPER & LOWER LIDS OCCASIONALLY. GET MD. SKIN:
REMOVE CONTAMINATED CLOTHING. WASH SKIN THOROUGHLY WITH SOAP &
WATER. IF IRRITATIO N OCCURS, GET MD. INHAL:REMOVE FROM EXPOSURE.
IF BREATHING HAS STOPPED OR IS DIFFICULT, GIVE ARTF RESP OR OXYGEN
AS INDICATED. GET MD. IF SYMPS PERSIST, CALL MD. INGEST:DO NOT
INDUCE VOMITING. GET MD.
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:SEE INGREDIENT 2
Lower Limits:1.1%
Upper Limits:6.1%
Extinguishing Media:SMALL FIRES:CARBON DIOXIDE, DRY CHEMICAL. LARGE
FIRES:FOAM OR WATER FOG (LARGE FIRES).
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL PROT
EQUIP . DENSE SMOKE SERIOUSLY LIMITS VISIBLILTY. VENT SMOKE.
Unusual Fire/Explosion Hazard:ISOLATE FROM HEAT, ELECTRICAL EQIUPMENT,
SPARKS AND OPEN FLAME.
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE ALL SOURCES OF IGNIT. INCR VENT TO
MAXIMIZE VAP DISPERSAL. DIKE LARGE SPILLS TO PVNT RUNOFF INTO
SEWERS OR WATERWAYS. MAY BE REMOVED BY ORDINARY PHYSICAL MEANS,
I.E., SHOVELING, WIPING. SWEEP/C LEAN W/INERT MATLS, SUCH AS SAND,
(SEE SUPP DATA)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN COOL, DRY AREA, OUT OF DIRECT
SUNLT. AVOID PRLNGD/RPTD CONTACT W/SKIN. AVOID EYE CONT. WORK
W/ADEQ GEN & LOC EXHST VENT TO MIN EXPOS TO VAPS.
Other Precautions:BOND & GROUND CNTNRS FOR TRANSFER OF PRODUCT TO
PREVENT STATIC SPARKS. STYRENE VAPS ARE UNINHIBITED & MAY CAUSE
BLOCKAGE OF VENTS DUE TO POLYMERIZATION. PERIODIC INSPECTION MAY BE
NEC TO PREVENT BLOCK AGE. AVOID IMPROPER (SUPP DATA)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE ADEQUATE VENTILATION. NIOSH/MSHA APPROVED
ORGANIC VAPOR/DUST RESPIRATOR TO AVOID INHALATION OF EXCESSIVE AIR
CONTAMINANTS.
Ventilation:LOC EXHST SHOULD BE USED TO CNTRL EMISSION OF AIR CONTAM.
GEN DILUTION VENT MAY ASSIST W/REDUCTION OF AIR CONTAM CONC.
Protective Gloves:POLYVINYL ALCOHOL AND POLYETHYLENE.
Eye Protection:CHEMCIAL WORKERS GOGGLES .
Other Protective Equipment:SAFETY SHOWERS AND EYE WASH STATIONS.
Work Hygienic Practices:CLEAN HANDS WITH SOAP & WATER AFTER EVERY USE.
Supplemental Safety and Health
SPILL PROC:VERMICULITE AND PLACE IN CLOSED CONTAINERS FOR DISPOSAL AS
SOLID WASTE. OTHER PREC:ADDITION OF PROMOTERS AND OXIDIZING AGENTS.
================== Physical/Chemical Properties ==================
HCC:F4
Boiling Pt:B.P. Text:ING 2
Vapor Pres:ING 2
Vapor Density:3.6
Spec Gravity:1.44
Evaporation Rate & Reference:LESS (ETHER=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:GREY, STYRENE ODOR
Percent Volatiles by Volume:<20
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS, PEROXIDES, AND OTHER OXIDIZING AGENTS.
Stability Condition to Avoid:UNREGULATED CONTACT WITH ORGANIC
PEROXIDES, EXPOSURE TO HEAT,OPEN FLAME, AND PROLONGED STORAGE ABOVE
100F.
Hazardous Decomposition Products:CO, CO2, LOW MOLECULAR WEIGHT
HYDROCARBONS, ORGANIC ACIDS.
Conditions to Avoid Polymerization:UNREGULATED CONTACT WITH ORGANIC
PEROXIDES, EXPOSURE TO HEAT, OPEN FLAME, AND PROLONGED STORAGE
ABOVE 100F.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND
LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.