DYNATRON/BONDO CORP -- 609 LIQUID HARDENER RED -- 8030-00F020131
===================== Product Identification =====================
Product ID:609 LIQUID HARDENER RED
MSDS Date:06/04/1988
FSC:8030
NIIN:00F020131
=== Responsible Party ===
Company Name:DYNATRON/BONDO CORP
Address:3700 ATLANTA INDUSTRIAL PARKWAY NW
City:ATLANTA
State:GA
ZIP:30331-1098
Info Phone Num:(800) 241-3386
Emergency Phone Num:(404) 696-2730 OR (404) 971-1502
Preparer's Name:S ABDUL RAZZAK
CAGE:16522
=== Contractor Identification ===
Company Name:BONDO/MAR-HYDE CORP
Address:3700 ATLANTA INDUSTRIAL PKWY NW
Box:City:ATLANTA
State:GA
ZIP:30331
Country:US
Phone:404-696-2730
CAGE:16522
============= Composition/Information on Ingredients =============
Ingred Name:DIMETHYL PHTHALATE
CAS:131-11-3
RTECS #:TI1575000
Fraction by Wt: 40-50%
Other REC Limits:5 MG/CUM
OSHA PEL:5 MG/CUM
ACGIH TLV:5 MG/CUM
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ingred Name:HYDROGEN PEROXIDE
CAS:7722-84-1
RTECS #:MX0900000
Fraction by Wt: 0-5%
Other REC Limits:1 PPM
OSHA PEL:1.4 MG/CUM
ACGIH TLV:1.4 MG/CUM
Ingred Name:METHYL ETHYL KETONE PEROXIDE
CAS:1338-23-4
RTECS #:WL9450000
Fraction by Wt: 40-50%
Other REC Limits:0.2 PPM
OSHA PEL:0.7 PPM
ACGIH TLV:C 1.5 MG/CUM
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS
===================== Hazards Identification =====================
LD50 LC50 Mixture:ORAL LD50 (RAT): 1017 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: MUCOUS MEMBRANE IRRITATION
& VERTIGO. EYES: DAMAGE. SKIN: IRRITATION & REDNESS. INGESTION:
HARMFUL, FATAL, & CORROSIVE.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INHALATION: MUCOUS MEMBRANE IRRITATION &
VERTIGO. EYES: DAMAGE. SKIN: IRRITATION & REDNESS. INGESTION:
HARMFUL, FATAL, & CORROSIVE.
Medical Cond Aggravated by Exposure:SKIN & RESPIRATORY CONDITIONS
======================= First Aid Measures =======================
First Aid:EYES: FLUSH W/WATER FOR AT LEAST 15 MINS. REMOVE CONTACT
LENSES IF THE INITIAL FLUSH DOESN'T WASH THEM OUT. GIVE IMMEDIATE
FIRST AID. SKIN: WASH W/SOAP & WATER FOR AT LEAST 15 MINS.
INHALATION: REMOVE TO FRESH AIR. IF NECESSARY, GIVE OXYGEN OR
ARTIFICIAL RESPIRATION. INGESTION: DON'T INDUCE VOMITING. GIVE
PLENTY OF WATER. OBTAIN MEDICAL ATTENTION IN ALL CASES.
===================== Fire Fighting Measures =====================
Flash Point Method:SCC
Flash Point:180F
Extinguishing Media:WATER FOG OR SPRAY, CO2, DRY CHEMICAL, OR FOAM
Fire Fighting Procedures:EVACUATE AREA/SUPPLY WATER FROM SAFE DISTANCE
TO COOL DOWN AREA. IF FIRE OCCURS NEAR PEROXIDE, SPRAY WATER ON
PEROXIDE CONTAINER TO PREVENT OVERHEATING.
Unusual Fire/Explosion Hazard:KETONE PEROXIDES ARE FLAMMABLE & CAN
IGNITE W/EXPLOSIVE FORCE IF CONFINED.
================== Accidental Release Measures ==================
Spill Release Procedures:PREVENT SPREAD OF SPILL. ABSORB W/SAND OR
INERT MATERIAL. SWEEP OR SCOOP OUT & REMOVE. REMOVE SATURATED
ABSORBENT W/NON-SPARKING TOOLS.
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID CONTACT W/SKIN/EYES/INHALATION
OF VAPORS/INGESTION. NEVER OPEN CONTAINER IN STORAGE ROOM. STORE IN
ORIGINAL PACKAGING.
Other Precautions:KEEP CONTAINERS TIGHTLY CLOSED IN WELL VENTILATED
AREA. DON'T STORE >85F. EMPTY CONTAINERS MAY CONTAIN HAZARDOUS
RESIDUE. NEVER CONTAMINATE W/ACCELERATORS (COBALT OCTOATE) AS
VIOLENT DECOMPOSITION MAY OCCUR. DON'T WEAR CONTACT LENSES.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE NIOSH APPROVED W/ORGANIC VAPOR CARTRIDGE TO
REDUCE HIGH CONTAMINANT CONCENTRATIONS IN INHALED AIR. RESPIRATOR
SELECTION DEPENDS UPON TYPE & MAGNITUDE OF EXPOSURE.
Ventilation:SUFFICIENT IN VOLUME & PATTERN TO KEEP 85F/THERMAL
DECOMPOSITION/CONTAMINATION/RADIATORS/STEAM PIPES/OTHER SOURCES OF
IGNITION
Hazardous Decomposition Products:KETONE PEROXIDE
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE W/FEDERAL, STATE,
& LOCAL REGULATIONS. THIS PRODUCT IS CLASSIFIED AS REACTIVE.
REPORTABLE QUANTITY: 20 LBS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.