DYNATRON/BONDO CORP -- DYNA-HAIR, 472 -- 8030-00N022728
===================== Product Identification =====================
Product ID:DYNA-HAIR, 472
MSDS Date:07/28/1990
FSC:8030
NIIN:00N022728
=== Responsible Party ===
Company Name:DYNATRON/BONDO CORP
Address:3700 ATLANTA INDUSTRIAL PARKWAY NW
City:ATLANTA
State:GA
ZIP:30331
Country:US
Info Phone Num:404-696-2730; 800-241-3386
Emergency Phone Num:404-696-2730;800-424-9300(CHEMTREC)
Preparer's Name:M WHEELOCK
CAGE:16522
=== Contractor Identification ===
Company Name:BONDO/MAR-HYDE CORP
Address:3700 ATLANTA INDUSTRIAL PKWY NW
Box:City:ATLANTA
State:GA
ZIP:30331
Country:US
Phone:404-696-2730
CAGE:16522
============= Composition/Information on Ingredients =============
Ingred Name:FIBROUS GLASS
CAS:65997-17-3
OSHA PEL:5 MG/M3 RDUST
ACGIH TLV:10 MG/M3
Ingred Name:UNSATURATED POLYESTER RESIN
Fraction by Wt: >50%
Ingred Name:STYRENE, MONOMER
CAS:100-42-5
RTECS #:WL3675000
Fraction by Wt: 16%
OSHA PEL:100 PPM
ACGIH TLV:S,50PPM/100STEL;9293
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:INERT POWDERS & FIBERS. CONSISTING OF INGREDIENTS 4, 5, AND
6.
RTECS #:9999999ZZ
Fraction by Wt: <50%
Ingred Name:TALC; (POWDER) CONTAINING NO ASBESTOS FIBERS
CAS:14807-96-6
RTECS #:WW2700000
OSHA PEL:2 MG/M3 (MFR)
ACGIH TLV:2 MG/M3 (MFR)
Ingred Name:SILICA GEL
CAS:1343-98-2
OSHA PEL:6 MG/M3 (MFR)
ACGIH TLV:6 MG/M3 (MFR)
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:(ACUTE) MAY CAUSE EYE AND SKIN
IRRITATION. VAPORS MAY CAUSE MUCOUS MEMBRANE IRRITATION AND UPPER
RESPIRATORY TRACT DISCOMFORT. (CHRONIC) REPEATED EXPOSURE TO HIGH
CONCENTRATIONS OF VAPOR MAY CAUSE LIV ER AND KIDNEY DAMAGE.
Explanation of Carcinogenicity:STYRENE: CLASS 2B (IARC).
Effects of Overexposure:EYES:MAY CAUSE IRRIT. LIQ SPLASHES MAY RESULT
IN MORE SERIOUS INJURIES. MAY CAUSE TEARING. SKIN: PRLNGD/FREQUENT
CONT MAY CAUSE DEFATTING & DRYNESS OF SKIN W/RESULTANT IRRIT & POSS
DERMAT. STYRENE MAY BE ABSORBED THRU SKIN IN TOX AMTS. INHAL:VAPS
MAY CAUSE MUC MEMB IRRIT & UPPER RESP TRACT DISCOMFORT. (SEE SUPP
DATA)
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH CHRONIC
RESPIRATORY CONDITIONS (I.E. ASTHMA, CHRONIC BRONCHITIS, EMPHYSEMA,
ETC) MAY BE ADVERSELY AFFECTED BY ANY FUME OR AIRBORNE PARTICULATE
MATTER EXPOSURE.
======================= First Aid Measures =======================
First Aid:EYES: FLUSH WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES.
SEEK IMMEDIATE MEDICAL AID. SKIN: WASH WITH SOAP AND WATER. INHAL:
REMOVE VICTIM FROM EXPOSURE. IF UNCONSCIOUS, ADMINISTER ARTIFICIAL
RESPIRAT ION AND/OR OXYGEN AS NEEDED. SEEK MEDICAL AID. INGEST: DO
NOT INDUCE VOMITING (ASPIRATION HAZARD). SEEK IMMEDIATE MEDICAL
AID.
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:90.0F,32.2C
Lower Limits:1.1%
Upper Limits:6.1%
Extinguishing Media:CO*2, DRY CHEMICAL (SMALL FIRES); FOAM AND WATER
FOG (LARGE FIRES).
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT . COOL CONTAINERS WITH WATER.
Unusual Fire/Explosion Hazard:HIGH TEMPERATURE EXPOSURE FOR EXTENDED
PERIODS OF TIME WILL RESULT IN SPONTANEOUS UNCONTROLLED EXOTHERMIC
POLYMERIZATION.
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENT AREA.
ABSORB SPILL WITH AN ABSORBENT MATERIAL SUCH AS SAWDUST,
VERMICULITE OR SAND AND PLACE IN A CLOSED CONTAINER. IF LARGE
SPILL, DIKE THE AREA TO PREVENT THIS M ATERIAL FROM ENTERING WATER
SYSTEMS OR SEWERS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID STORAGE ABOVE 100F. AVOID
PROLONGED OR REPEATED SKIN CONTACT. AVOID INHAL OF VAPORS OR SPRAY
MISTS. KEEP OUT OF REACH OF CHILDREN.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH/MSHA APPROVED ORGANIC VAPOR RESPIRATOR IF
PEL OR TLV IS EXCEEDED. APPROPRIATE RESPIRATOR SELECTION DEPENDS
UPON TYPE AND MAGNITUDE OF EXPOSURE.
Ventilation:GENERAL VENT IS REQUIRED DURING NORMAL USE. LOCAL VENT MAY
BE REQUIRED DURING CERTAIN OPER TO KEEP EXPOS LEV