XEROX CORP -- 7041/7042 TONER, 106R67 -- 6850-00N080804
=====================  Product Identification  =====================

Product ID:7041/7042 TONER, 106R67
MSDS Date:04/19/1995
FSC:6850
NIIN:00N080804
=== Responsible Party ===
Company Name:XEROX CORP
Address:XEROX SQ 100 CLINTON AVE S
City:ROCHESTER
State:NY
ZIP:14644-1877
Country:US
Info Phone Num:800-828-6571;716-423-5090
Emergency Phone Num:716-422-2177;716-422-2177
CAGE:0E6G9
=== Contractor Identification ===
Company Name:XEROX CORP
Address:300 MAIN ST NO 27C
City:EAST ROCHESTER
State:NY
ZIP:14645
Country:US
Phone:800-828-6571; 800-351-2024
CAGE:0E6G9
Company Name:XEROX CORPORATION
Address:100 CLINTON AVE SOUTH
Box:City:ROCHESTER
State:NY
ZIP:14644-1877
Country:US
Phone:800-828-6571/716-422-2177
CAGE:26921

=============  Composition/Information on Ingredients  =============

Ingred Name:IRON OXIDE
CAS:1309-37-1
RTECS #:NO7400000
Fraction by Wt: 50-60%
OSHA PEL:10 MG/M3 (FE)
ACGIH TLV:5 MG(FE)/M3 FUME

Ingred Name:BUTADIENE-STYRENE POLYMER (RUBBER)
CAS:9003-55-8
RTECS #:WL6478000
Fraction by Wt: 40-50%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:POLYPROPYLENE WAX
Fraction by Wt: 2-5%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:SILICA, AMORPHOUS, DIATOMACEOUS EARTH
CAS:61790-53-2
RTECS #:HL8600000
Fraction by Wt: <1%
OSHA PEL:20 MPPCF; Z-3
ACGIH TLV:10 MG/M3 TDUST

Ingred Name:ZINC STEARATE
CAS:557-05-1
RTECS #:ZH5200000
Fraction by Wt: <1%
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:N/K 

Ingred Name:SUPDAT:MAY BE WASHED OR DRY CLEANED, AFTER REMOVAL OF LOOSE
    TONER.
RTECS #:9999999ZZ

Ingred Name:OTHER PROT EQUIP:IN BULK TONER PROCESSING FACILITIES),
    GOGGS & NIOSH APPRVD RESPS MAY BE REQD. FOR MORE (ING 8)
RTECS #:9999999ZZ

Ingred Name:ING 7:INFORMATION, CONTACT XEROX.
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:LD50:(ORAL,RAT) >5 G/KG
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: MINIMAL RESP TRACT IRRIT MAY
    OCCUR AS W/EXPOS TO LARGE AMTS OF ANY NON-TOXIC DUST. ADDNL INFO:
    RSLTS OBTAINED FROM MFR SPONSORED, CHRONIC TONER INHAL STUDY,
    DEMONSTRATED NO LUNG CHANGE IN RATS  FOR LOWEST (1 MG/M3) EXPOS
    LEVEL (I.E. LEVEL MOST RELEVANT TO POTNTL HUMAN EXPOS). VERY SLIGHT
    DEGREE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: OF FIBROSIS WAS NOTED IN 1/4 OF
    ANIMALS @ MIDDLE (4 MG/M3) EXPOS LEVEL, WHILE SLIGHT DEGREE OF
    FIBROSIS WAS NOTED IN ALL ANIMALS @ HIGHEST (16 MG/M3) EXPOS LEVEL.
    THESE FINDINGS ARE ATTRIBUT ED TO "LUNG OVERLOADING", GENERIC
    RESPONSE TO EXCESS AMTS OF ANY DUST RETAINED IN LUNGS FOR PRLNGD
    PERIOD. THIS (SUPDAT)
Medical Cond Aggravated by Exposure:NONE WHEN USED AS DESCRIBED BY
    PRODUCT LITERATURE.

=======================  First Aid Measures  =======================

First Aid:EYES: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. SKIN: WASH
    WITH SOAP AND WATER. INHALATION: REMOVE FROM EXPOSURE. INGESTION:
    DILUTE STOMACH CONTENTS WITH SEVERAL GLASSES OF WATER.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:WATER SPRAY, FOAM, DRY POWDER.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT . AVOID INHALATION OF SMOKE.
Unusual Fire/Explosion Hazard:TONER IS A COMBUSTIBLE POWDER. LIKE MOST
    ORGANIC MATLS IN POWDER FORM, WHEN DISPERSED IN AIR; IT CAN FORM
    EXPLOSIVE MIXTURES.

==================  Accidental Release Measures  ==================

Spill Release Procedures:SWEEP UP/VACUUM SPILLED DRY INK & CAREFULLY
    TRANSFER INTO SEALABLE CNTNR. SWEEP SLOWLY TO MINIMIZE GENERATION
    OF DUST DURING CLEAN-UP. IF VACUUM IS USED, MOTOR MUST BE RATED AS
    DUST TIGHT. CONDUCTIVE  HOSE BONDED TO MACHINE SHOULD BE USED TO
    (SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:NONE.
Other Precautions:AVOID PROLONGED INHALATION OF EXCESSIVE DUST.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE REQUIRED WHEN USED AS INTENDED. NIOSH
    APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER . FOR
    USE OTHER THAN NORMAL CUSTOMER-OPERATING PROCEDURES (SUCH AS (ING
    7)
Work Hygienic Practices:WASH SKIN THOROUGHLY IN CASE OF SKIN CONTACT.
Supplemental Safety and Health
EFTS OF OVEREXP: STUDY WAS CONDUCTED USING SPEC TEST TONER TO COMPLY
    W/EPA TESTING PROTOCOL. TEST TONER WAS 10 TIMES MORE RESPIRABLE
    THAN COMMERCIALLY AVAIL XEROX TONER, & WOULD NOT BE FUNCTIONALLY SU
    ITABLE FOR XEROX EQUIP. SPILL PROC:REDUCE STATIC BUILD UP. RESIDUE
    CAN BE REMOVED W/SOAP & COLD WATER. GARMENTS (ING 6)

==================  Physical/Chemical Properties  ==================

Melt/Freeze Pt:M.P/F.P Text:284F,140C
Spec Gravity:1.8 (H*2O=1)
Solubility in Water:INSOLUBEL
Appearance and Odor:BLACK POWDER

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CO, CO*2, AND OTHER TOXIC PRODUCTS OF
    COMBUSTION. AVOID BREATHING SMOKE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:WHEN DISPOSED, THIS MATL IS NOT HAZ WASTE
    ACCORDING TO FED REG 40 CFR 261 WHEN DISPOSED. STATE & LOC
    REQUIREMENTS MAY HOWEVER BE MORE RESTRICTIVE. CONSULT W/APPROP FED,
    STATE & LOCAL WASTE DISP AUTH F OR DETAILED INFO. INCIN ONLY IN A
    CLSD CNTNR.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.