CUSTOM AEROSOL PACKAGING -- AEROSOL,PAINT -- 8010-00-137-9150
=====================  Product Identification  =====================

Product ID:AEROSOL,PAINT
MSDS Date:08/31/1988
FSC:8010
NIIN:00-137-9150
Status Code:A
=== Responsible Party ===
Company Name:CUSTOM AEROSOL PACKAGING
Address:128 E WATER ST
City:PIQUA
State:OH
ZIP:45356
Country:US
Info Phone Num:513-773-1824
Emergency Phone Num:800-424-9300
Preparer's Name:ERNEST CARTER
Chemtrec Ind/Phone:(800)424-9300
CAGE:0G0J3
=== Contractor Identification ===
Company Name:CUSTOM AEROSOL PACKAGING
Address:128 E WATER ST
Box:City:PIQUA
State:OH
ZIP:45356
Country:US
Phone:513-773-1824
CAGE:0G0J3

=============  Composition/Information on Ingredients  =============

Ingred Name:VM&P NAPTHA
CAS:8030-30-6
Code:F
RTECS #:DE3030000
= Wt:10.
OSHA PEL:400 MG/M3;100 PPM
ACGIH TLV:1590 MG/M3;400 PPM

Ingred Name:XYLENE
CAS:1330-20-7
RTECS #:ZE2100000
< Wt:5.1
ACGIH TLV:434 MG/M3;100 PPM
ACGIH STEL:651 MG/M3;150 PPM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:SECONDARY BUTYL ALCOHOL OR 2-BUTYL
< Wt:5.

Ingred Name:AROMATIC HYDROCARBON
CAS:64742-95-6
Code:F
RTECS #:WF3400000
< Wt:5.

Ingred Name:LOW ODOR MINERAL SPIRITS
CAS:8032-32-4
Code:F
RTECS #:OI6180000
< Wt:5.
ACGIH TLV:1370 MG/M3;300 PPM

Ingred Name:ACETONE
CAS:67-64-1
RTECS #:AL3150000
= Wt:15.
OSHA PEL:2400 MG/M3;1000 PPM
ACGIH TLV:1780 MG/M3;750 PPM
ACGIH STEL:2380 MG/M3;1000 PPM
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:METHYL ISO-BUTYL KETONE
CAS:108-10-1
RTECS #:SA9275000
< Wt:5.
OSHA PEL:410 MG/M3;100 PPM
ACGIH TLV:205 MG/M3;50 PPM
ACGIH STEL:307 MG/M3;75 PPM
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:N-BUTYL ALCOHOL
CAS:71-36-3
RTECS #:EO1400000
< Wt:5.
OSHA PEL:300 MG/M3;100 PPM
ACGIH STEL:C152 MG/M3;C50 PPM
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:1,1,1-TRICHLOROETHANE
CAS:71-55-6
RTECS #:KJ2975000
= Wt:25.
OSHA PEL:1900 MG/M3;350 PPM
ACGIH TLV:1910 MG/M3;350 PPM
ACGIH STEL:2460 MG/M3;450 PPM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ozone Depleting Chemical:1

Ingred Name:PROPANE
CAS:74-98-6
RTECS #:TX2275000
= Wt:15.
OSHA PEL:1800 MG/M3;1000 PPM

Ingred Name:ISOBUTANE
CAS:75-28-5
RTECS #:TI4300000
= Wt:5.

=====================  Hazards Identification  =====================

Effects of Overexposure:INGESTION: HARMFUL OR FATAL IF SWALLOWED. EYE
    CONTACT: PRIMARY IRRITANT. SKIN CONTACT: PRIMARY IRRITANT.
    INHALATION: HIGH CONCENTRATIONS OF VAPORS ARE ANESTHETIC, WILL
    IRRITATE THE RESPIRATORY TRACT A ND CAUSE NERVOUS SYSTEM DEPRESSION
    CHARACTERIZED BY DROWSINESS, LIGHTHEADEDNESS, HEADACHE, DIZZINESS,
    STAGGERING, CONFUSION, UNCONSCIOUSNESS OR COMA.
Medical Cond Aggravated by Exposure:REPORTS HAVE SHOWN THAT REPEATED
    AND PROLONGED OCCUPATIONAL OVEREXPOSURE TO SOLVENTS MAY CAUSE
    PERMANENT BRAIN AND NERVOUS SYSTEM DAMAGE.

=======================  First Aid Measures  =======================

First Aid:INGESTION: DO NOT INDUCE VOMITING. CALL PHYSICIAN
    IMMEDIATELY. EYE CONTACT: FLUSH IMMEDIATELY WITH LARGE AMOUNTS OF
    WATER FOR 15 MINUTES. CALL PHYSICIAN IMMEDIATELY. SKIN CONTACT:
    WASH AFFECTED AREA W ITH SOAP AND WATER, REMOVE CONTAMINATED
    CLOTHING. INHALATION: REMOVE TO FRESH AIR. IF NECESSARY APPLY
    ARTIFICIAL RESPIRATION AND/OR OXYGEN. CALL PHYSICIAN.

=====================  Fire Fighting Measures  =====================

Flash Point Method:PMCC
Lower Limits:2.3
Extinguishing Media:NFPA CLASS B EXTINGUISHERS. (CARBON DIOXIDE, DRY
    CHEMICAL OR FOAM).
Fire Fighting Procedures:WATER SPRAY MAY BE INEFFECTIVE BUT MAY BE USED
    TO COOL CLOSED CONTAINERS TO PREVENT PRESSURE BUILD UP AND POSSIBLE
    AUTOIGNITION OR EXPLOSION WHEN EXPOSED TO EXTREME HEAT. IF WATER IS
    USED. FOG NOLLES  ARE PREFERABLE. FIRE FIGHTERS SHOULD WEAR SELF
    CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:KEEP CONTAINERS TIGHTLY CLOSED. ISOLATE
    FROM HEAT, ELECTRICAL EQUIPMENT, SPARKS AND OPEN FLAMES. CLOSED
    CONTAINERS MAY EXPLODE WHEN EXPOSED TO EXTREME HEAT. DO NOT APPLY
    ON HOT SURFACES. TOXIC GASES M AY FORM WHEN PRODUCT IS CONTACTED BY
    FLAME OR HOT SURFACES. AEROSOL CONTAINERS HOLD EXTREMELY FLAMMABLE
    GAS AND FLAMMAB

==================  Accidental Release Measures  ==================

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION AND PROVIDE
    MAXIMUM VENTILATION. EQUIP. PERSONNEL WITH PROPER RESPIRATORY, SKIN
    AND EYE PROTECTION. TAKE UP SPILLED MATERIAL WITH SAWDUST,
    VERMICULITE OR OTHER ABSORBENT  MATERIAL AND PLACE IN CONTAINERS
    FOR DISPOSAL.

======================	Handling and Storage  ======================

Handling and Storage Precautions:DO NOT STORE ABOVE 120 F. KEEP AWAY
    FROM HEAT, SPARKS, AND OPEN FLAMES. DO NOT PUNCTURE. KEEP OUT OF
    REACH OF CHILDREN.
Other Precautions:USE ONLY AROUND EXPLOSION PROOF EQUIPMENT. AVOID
    PROLONGED BREATHING OF VAPORS. AVOID CONTACT WITH SKIN. DO NOT TAKE
    INTERNALLY. INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING AND
    INHALING THE CONTE NTS OF THE AEROSOL CAN BE HARMFU

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:WERA NIOSH/MSHA APPROVED (TC-23-C) PAINT SPRAY
    OR (TC-19-C) AIR SUPPLIED RESPIRATOR.
Ventilation:PROVIDE GENERAL DILUTION OR LOCAL EXHAUST VENTILATION IN
    VOLUME AND PATTERN TO KEEP THE CONCENTRATION OF INGREDIENTS LISTED
    IN SECTION II.
Protective Gloves:WEAR PROTECTIVE CLOTHING INCLUDING APRON AND GLOVES.
Eye Protection:WEAR CHEMICAL TYPE GOGGLES OR FACE SHIELD.
Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

Boiling Pt:<-17.6C, 0.F
Vapor Pres:<78 MMHG
Vapor Density:HEAVIER
Spec Gravity:.7-.8
VOC Grams/Liter:6.7
Evaporation Rate & Reference:(BU0AC=100): <57
Solubility in Water:21-4%
Percent Volatiles by Volume:85-96%

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
AVOID STRONG ALKALIES, STRONG MINERAL ACIDS AND STRONG OXIDIZING
    AGENTS.
Hazardous Decomposition Products:CARBON MONOXIDE AND CARBON DIOXIDE
    WHEN HEATED.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF ACCORDING TO LOCAL, STATE AND FEDERAL
    ERGULATIONS. DO NOT INCINERATE CLOSED CONTAINER.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.