DYNATRON/BONDO CORP -- 592 PUTTY COTE -- 8010-00F019988
=====================  Product Identification  =====================

Product ID:592 PUTTY COTE
MSDS Date:06/04/1988
FSC:8010
NIIN:00F019988
MSDS Number: BMHMG
=== Responsible Party ===
Company Name:DYNATRON/BONDO CORP
Address:3700 ATLANTA INDUSTRIAL PKY NW
City:ATLANTA
State:GA
ZIP:30331-1098
Info Phone Num:(404) 696-2730 OR (800) 241-3386
Emergency Phone Num:(404) 696-2730 OR 971-1502
Preparer's Name:S. ABDUL RAZZAK
CAGE:16522
=== Contractor Identification ===
Company Name:BONDO/MAR-HYDE CORP
Address:3700 ATLANTA INDUSTRIAL PKWY NW
Box:City:ATLANTA
State:GA
ZIP:30331
Country:US
Phone:404-696-2730
CAGE:16522

=============  Composition/Information on Ingredients  =============

Ingred Name:STYRENE, (MONOMER), SUSPECTED ANIMAL CARCINOGEN BY IARC &
    ACGIH
CAS:100-42-5
RTECS #:WL3675000
Fraction by Wt: <20%
Other REC Limits:50 PPM
OSHA PEL:100 PPM
ACGIH TLV:S,50PPM/100STEL;9293
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:TALC (POWDER), (ASBESTOS FREE), TALCUM, MAGNESIUM SILICATE
CAS:14807-96-6
RTECS #:WW2710000
Fraction by Wt: <50%
OSHA PEL:20 MPPCF
ACGIH TLV:2 MG/CUM (RESP DUST)

Ingred Name:SILICON DIOXIDE
CAS:7631-86-9
RTECS #:VV3100000
Fraction by Wt: <50%
OSHA PEL:20 MPPCFM
ACGIH TLV:10 MG/CUM DUST

Ingred Name:UNSATURATED POLYESTER RESIN
Fraction by Wt: <50%

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:YES	 OSHA:NO
Health Hazards Acute and Chronic:EYES: IRRITATION. SKIN: IRRITATION,
    RASH, DERMATITIS, & ECZEMATOUS. INHALATION: DRUGGED FEELING,
    SLEEPINESS, UNCONSCIOUSNESS, & UPPER RESPIRATORY IRRITATION.
Explanation of Carcinogenicity:STYRENE IS A SUSPECTED ANIMAL
    CARCINOGEN.
Effects of Overexposure:EYES: IRRITATION. SKIN: IRRITATION, RASH,
    DERMATITIS, & ECZEMATOUS. INHALATION: DRUGGED FEELING, SLEEPINESS,
    UNCONSCIOUSNESS, & UPPER RESPIRATORY IRRITATION.
Medical Cond Aggravated by Exposure:CHRONIC RESPIRATORY CONDITIONS SUCH
    AS ASTHMA, CHRONIC BRONCHITIS, OR EMPHYSEMA.

=======================  First Aid Measures  =======================

First Aid:EYES: FLUSH W/WATER FOR AT LEAST 15 MINS. SKIN: WASH W/SOAP &
    WATER. INHALATION: REMOVE TO FRESH AIR. IF BREATHING STOPS
    ADMINISTER ARTIFICIAL RESPIRATION. IF BREATHING IS DIFFICULT,
    ADMINISTER OXYGEN . INGESTION: DON'T INDUCE VOMITING. OBTAIN
    MEDICAL ATTENTION IN ALL CASES.

=====================  Fire Fighting Measures  =====================

Flash Point Method:PMCC
Flash Point:90F (STYRENE)
Lower Limits:1.1%
Upper Limits:6.1%
Extinguishing Media:CO2, DRY CHEMICAL, FOAM, OR WATER FOG
Fire Fighting Procedures:WEAR MSHA/NIOSH APPROVED SELF-CONTAINED
    BREATHING APPARATUS W/PROTECTIVE EQUIPMENT. VENT DENSE SMOKE & USE
    GAS MASK OR REMOTE AIR SUPPLY.

==================  Accidental Release Measures  ==================

Spill Release Procedures:REMOVE ALL IGNITION SOURCES. INCREASE
    VENTILATION TO MAXIMIZE VAPOR DISPERSAL. DIKE SPILL TO PREVENT
    RUNOFF INTO SEWERS/WATERWAYS. SHOVEL/WIPE/SWEEP OR CLEAN W/INERT
    MEATERIALS SUCH AS SAND/VERMICULIT E & PLACE IN CLOSED CONTAINER
    FOR DISPOSAL.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN COOL, DRY AREA OUT OF DIRECT
    SUNLIGHT. USE W/ADEQUATE VENTILATION. BOND/GROUND CONTAINERS FOR
    TRANSFER TO PREVENT STAIC SPARKS.
Other Precautions:AVOID CONTACT W/SKIN/EYES. STYRENE VAPORS ARE
    UNINHIBITED & MAY CAUSE BLOCKAGE OF VENTILATION VENTS DUE TO
    POLYMERIZATION. PERIODIC INSPECTION MAY BE NECESSARY TO PREVENT
    BLOCKAGE. AVOID IMPROPER ADDI TION OF PROMOTORS/OXIDIZING AGENTS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE NIOSH/MSHA APPROVED ORGANIC VAPOR/DUST
    RESPIRATOR.
Ventilation:LOCAL EXHAUST OR GENERAL DILUTION TO KEEP 100F &
    DIRECT SUNLIGHT
Hazardous Decomposition Products:CO, CO2, LOW MOLECULAR WEIGHT
    HYDROCARBONS, & ORGANIC ACIDS
Conditions to Avoid Polymerization:UNREGULATED CONTACT W/ORGANIC
    PEROXIDES, EXPOSURE TO HEAT, OPEN FLAME & PROLONGED STORAGE >100F.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF AS SOLID WASTE IN ACCORDANCE
    W/FEDERAL, STATE, & LOCAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.