XEROX CORP -- 7041/7042 DOCUMENT WORK CENTER -- 6850-00N080804
=====================  Product Identification  =====================

Product ID:7041/7042 DOCUMENT WORK CENTER
MSDS Date:05/07/1998
FSC:6850
NIIN:00N080804
Status Code:A
=== Responsible Party ===
Company Name:XEROX CORP
Address:100 CLINTON AVE S
City:ROCHESTER
State:NY
ZIP:14644
Country:US
Info Phone Num:800-828-6571
Emergency Phone Num:716-422-2177
CAGE:0E6G9
=== Contractor Identification ===
Company Name:XEROX CORP
Address:300 MAIN ST NO 27C
City:EAST ROCHESTER
State:NY
ZIP:14645
Country:US
Phone:800-828-6571; 800-351-2024
CAGE:0E6G9
Company Name:XEROX CORPORATION
Address:100 CLINTON AVE SOUTH
Box:City:ROCHESTER
State:NY
ZIP:14644-1877
Country:US
Phone:800-828-6571/716-422-2177
CAGE:26921

=============  Composition/Information on Ingredients  =============

Ingred Name:IRON OXIDE
CAS:1317-61-9
Fraction by Wt: 50-65%
OSHA PEL:10 MG/M3
ACGIH TLV:5 MG/M3

Ingred Name:STYRENE/ACRYLIC POLYMER
CAS:25036-16-2
Fraction by Wt: 40-50%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:POLYPROPYLENE WAX
CAS:9003-07-4
RTECS #:UD1842000
Fraction by Wt: 1-5%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:SILICON DIOXIDE (AMORPHOUS); (AMORPHOUS SILICA)
CAS:67762-90-7
Fraction by Wt: 0.1-1%
OSHA PEL:6 MG/M3
ACGIH TLV:10 MG/M3

Ingred Name:SUPP DATA:DUST RETAINED IN LUNGS FOR PRLNG PERIOD. THIS
    STUDY WAS CONDUCTED USING A SPECIAL TEST TONER TO COMPLY (ING 6)
RTECS #:9999999ZZ

Ingred Name:ING 5:W/EPA TESTING PROTOCOL. THE TEST TONER WAS 10 TIMES
    MORE RESPIRABLE THAN COMMERCIALLY AVAIL XEROX TONER, & (ING 7)
RTECS #:9999999ZZ

Ingred Name:ING 6:WOULD NOT BE FUNCTIONALLY SUITABLE FOR XEROX
    EQUIPMENT.
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:LD50:(ORAL,RAT) >5 G/KG.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:MINIMAL RESPIRATORY TRACT IRRITATION
    MAY OCCUR AS WITH EXPOSURE TO LARGE AMOUNTS OF ANY NON-TOXIC DUST.
    TOX INFO:ORAL/DERMAL:PRACTICALLY NON-TOXIC. INHAL:PRACTICALLY
    NON-TOXIC. NON-POIS. EYE:NOT IRRIT . SKIN:NOT SENSITIZER. NOT
    IRRIT. THE RSLTS OBTAINED FROM XEROX SPONSORED, CHRONIC TONER INHAL
    STUDY, (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:DEMONSTRATED NO LUNG CHANGE IN RATS
    FOR LOWEST (1 MG/M3) EXPOS LEVEL (I.E. LEVEL MOST RELEVANT TO
    POTNTL HUMAN EXPOS). A VERY SLIGHT DEGREE OF FIBROSIS WAS NOTED IN
    1/4 OF ANIMALS AT MIDDLE ( 4 MG/M3) EXPOS LEVEL, WHILE A SLIGHT
    DEGREE OF FIBROSIS WAS NOTED IN ALL ANIMALS AT HIGHEST (16 MG/M3)
    EXPOS (SUPP DATA)
Medical Cond Aggravated by Exposure:NONE WHEN USED AS DESCRIBED BY
    PRODUCT LITERATURE.

=======================  First Aid Measures  =======================

First Aid:EYES:FLUSH W/WATER FOR AT LEAST 15 MINUTES. SKIN:WASH W/SOAP
    & WATER. INHAL:REMOVE FROM EXPOSURE. INGEST:DILUTE STOMACH CONTENTS
    W/SEVERAL GLASSES OF WATER.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:WATER SPRAY, FOAM, DRY POWDER.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT . AVOID INHALATION OF SMOKE.
Unusual Fire/Explosion Hazard:TONER IS A COMBUSTIBLE POWDER. LIKE MOST
    ORGANIC MATERIALS IN POWDER FORM, IT CAN FORM EXPLOSIVE MIXTURES
    WHEN DISPERSED IN AIR.

==================  Accidental Release Measures  ==================

Spill Release Procedures:SWEEP UP/VACUUM SPILLED TONER & CAREFULLY
    TRANSFER INTO SEALABLE WASTE CNTNR. SWEEP SLOWLY TO MIN GENERATION
    OF DUST DURING CLEAN-UP. IF VACUUM IS USED, MOTOR MUST BE RATED AS
    DUST TIGHT. CONDUCTIVE H OSE BONDED TO MACHINE SHOULD BE USED
    TO(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:AVOID PROLONGED INHALATION OF
    EXCESSIVE DUST.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE REQUIRED WHEN USED AS INTENDED IN XEROX
    EQUIPMENT. FOR USE OTHER THAN NORMAL CUSTOMER-OPERATING PROCEDURES
    (SUCH AS IN BULK TONER PROCESSING FACILITIES), NIOSH APPROVED
    RESPIRATORS MAY BE REQUIRE D. FOR MORE INFORMATION, CONTACT XEROX.
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
    ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPILL PROC:REDUCE STATIC BUILDUP. RESIDUE CAN BE REMOVED W/SOAP & COLD
    WATER. GARMENTS MAY BE WASHED/DRY CLEANED, AFTER REMOVAL OF LOOSE
    TONER. WASTE DISP METH:INFO. INCIN ONLY IN CLSD CNTNR. EFTS OF 
    OVEREXP:LEVEL. THESE FINDINGS ARE ATTRIBUTED TO "LUNG OVERLOADING",
    A GENETIC RESPONSE TO EXCESSIVE AMTS OF ANY (ING 5)

==================  Physical/Chemical Properties  ==================

Spec Gravity:3.5 (H*2O=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:BLACK POWDER; FAINT ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CO, CO*2 & OTHER TOXIC PRODUCTS OF
    COMBUSTION. AVOID BREATHING SMOKE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISP MUST BE I/A/W FED, STATE & LOC REGS . THIS
    MATL IS NOT HAZ WASTE ACCORDING TO FED REG 40 CFR 261 WHEN
    DISPOSED. STATE & LOC WASTE DISP REQUIREMENTS MAY BE MORE
    RESTRICTIVE. CONSULT W/APPROP  STATE & LOC WASTE DISP AUTHS FOR
    ADDNL(SUPDAT)

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.