DYNATRON/BONDO CORPORATION -- 428 FIBERGLASS PANEL ADHESIVE -- 8040-00N019641
=====================  Product Identification  =====================

Product ID:428 FIBERGLASS PANEL ADHESIVE
MSDS Date:06/04/1988
FSC:8040
NIIN:00N019641
=== Responsible Party ===
Company Name:DYNATRON/BONDO CORPORATION
Address:3700 ATLANTA INDUSTRIAL PARKWAY NW
City:ATLANTA
State:GA
ZIP:30331-1098
Country:US
Info Phone Num:800-241-3386
Emergency Phone Num:404-696-2730 OR 404-971-1502
Preparer's Name:S ABDUL RAZZAK
CAGE:16522
=== Contractor Identification ===
Company Name:BONDO/MAR-HYDE CORP
Address:3700 ATLANTA INDUSTRIAL PKWY NW
Box:City:ATLANTA
State:GA
ZIP:30331
Country:US
Phone:404-696-2730
CAGE:16522

=============  Composition/Information on Ingredients  =============

Ingred Name:UNSATURATED POLYESTER RESINS
CAS:26123-45-5
Fraction by Wt: >50%

Ingred Name:STYRENE, MONOMER  (SARA III)
CAS:100-42-5
RTECS #:WL3675000
Fraction by Wt: <20%
OSHA PEL:100 PPM
ACGIH TLV:S,50PPM/100STEL;9293
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:TALC (CONTAINING NO ASBESTOS)
CAS:14807-96-6
RTECS #:WW2710000
Fraction by Wt: <50%
OSHA PEL:2 MG/M3 RDUST
ACGIH TLV:2 MG/M3 RDUST; 9192

Ingred Name:FIBROUS GLASS
CAS:65997-17-3
OSHA PEL:15 MG/M3 (MFR)
ACGIH TLV:10 MG/M3 (MFR)

Ingred Name:MUSCOVITE;(SILICEOUS MICA)
CAS:1318-94-1
OSHA PEL:3 MG/M3 RDUST
ACGIH TLV:3 MG/M3 RDUST

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:YES	 OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYE AND UPPER RESPIRATORY
    IRRITATION FROM VAPOR INHALATION. MINOR SKIN IRRITATION FROM
    CONTACT WITH MATERIAL. CHRONIC:MAY FEEL DRUGGED, BECOME SLEEPY OR
    UNCONSCIOUS. REPEATED SKIN CONTACT MAY CA USE RASH, WITH PROLONGED
    EXPOSURE POSSIBLE DEVELOPING TO DERMATITIS. IF ECZEMATOUS DEVELOPS,
    THIS (EFTS OF OVEREXPOSURE)
Explanation of Carcinogenicity:STYRENE:CLASS 2B (IARC).
Effects of Overexposure:HLTH HAZ:MOST OFTEN OCCURS ON THE BACK OF
    HANDS, WRISTS AND FOREARMS.
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH CHRONIC
    RESPIRATORY CONDITIONS (I.E., ASTHMA, CHRONIC BRONCHITIS,
    EMPHYSEMA, ETC.) MAY BE ADVERSELY AFFECTED BY ANY FUME OR AIRBORNE
    PARTICULATE MATTER EXPOSURE.

=======================  First Aid Measures  =======================

First Aid:EYE:FLUSH WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15
    MINUTES, LIFTING UPPER & LOWER LIDS OCCASIONALLY. GET MD. SKIN:
    REMOVE CONTAMINATED CLOTHING. WASH SKIN THOROUGHLY WITH SOAP &
    WATER. IF IRRITATIO N OCCURS, GET MD. INHAL:REMOVE FROM EXPOSURE.
    IF BREATHING HAS STOPPED OR IS DIFFICULT, GIVE ARTF RESP OR OXYGEN
    AS INDICATED. GET MD. IF SYMPS PERSIST, CALL MD. INGEST:DO NOT
    INDUCE VOMITING. GET MD.

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:SEE INGREDIENT 2
Lower Limits:1.1%
Upper Limits:6.1%
Extinguishing Media:SMALL FIRES:CARBON DIOXIDE, DRY CHEMICAL. LARGE
    FIRES:FOAM OR WATER FOG (LARGE FIRES).
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL PROT
    EQUIP . DENSE SMOKE SERIOUSLY LIMITS VISIBLILTY. VENT SMOKE.
Unusual Fire/Explosion Hazard:ISOLATE FROM HEAT, ELECTRICAL EQIUPMENT,
    SPARKS AND OPEN FLAME.

==================  Accidental Release Measures  ==================

Spill Release Procedures:REMOVE ALL SOURCES OF IGNIT. INCR VENT TO
    MAXIMIZE VAP DISPERSAL. DIKE LARGE SPILLS TO PVNT RUNOFF INTO
    SEWERS OR WATERWAYS. MAY BE REMOVED BY ORDINARY PHYSICAL MEANS,
    I.E., SHOVELING, WIPING. SWEEP/C LEAN W/INERT MATLS, SUCH AS SAND,
    (SEE SUPP DATA)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN COOL, DRY AREA, OUT OF DIRECT
    SUNLT. AVOID PRLNGD/RPTD CONTACT W/SKIN. AVOID EYE CONT. WORK
    W/ADEQ GEN & LOC EXHST VENT TO MIN EXPOS TO VAPS.
Other Precautions:BOND & GROUND CNTNRS FOR TRANSFER OF PRODUCT TO
    PREVENT STATIC SPARKS. STYRENE VAPS ARE UNINHIBITED & MAY CAUSE
    BLOCKAGE OF VENTS DUE TO POLYMERIZATION. PERIODIC INSPECTION MAY BE
    NEC TO PREVENT BLOCK AGE. AVOID IMPROPER (SUPP DATA)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE ADEQUATE VENTILATION. NIOSH/MSHA APPROVED
    ORGANIC VAPOR/DUST RESPIRATOR TO AVOID INHALATION OF EXCESSIVE AIR
    CONTAMINANTS.
Ventilation:LOC EXHST SHOULD BE USED TO CNTRL EMISSION OF AIR CONTAM.
    GEN DILUTION VENT MAY ASSIST W/REDUCTION OF AIR CONTAM CONC.
Protective Gloves:POLYVINYL ALCOHOL AND POLYETHYLENE.
Eye Protection:CHEMCIAL WORKERS GOGGLES .
Other Protective Equipment:SAFETY SHOWERS AND EYE WASH STATIONS.
Work Hygienic Practices:CLEAN HANDS WITH SOAP & WATER AFTER EVERY USE.
Supplemental Safety and Health
SPILL PROC:VERMICULITE AND PLACE IN CLOSED CONTAINERS FOR DISPOSAL AS
    SOLID WASTE. OTHER PREC:ADDITION OF PROMOTERS AND OXIDIZING AGENTS.

==================  Physical/Chemical Properties  ==================

HCC:F4
Boiling Pt:B.P. Text:ING 2
Vapor Pres:ING 2
Vapor Density:3.6
Spec Gravity:1.44
Evaporation Rate & Reference:LESS (ETHER=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:GREY, STYRENE ODOR
Percent Volatiles by Volume:<20

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS, PEROXIDES, AND OTHER OXIDIZING AGENTS.
Stability Condition to Avoid:UNREGULATED CONTACT WITH ORGANIC
    PEROXIDES, EXPOSURE TO HEAT,OPEN FLAME, AND PROLONGED STORAGE ABOVE
    100F.
Hazardous Decomposition Products:CO, CO2, LOW MOLECULAR WEIGHT
    HYDROCARBONS, ORGANIC ACIDS.
Conditions to Avoid Polymerization:UNREGULATED CONTACT WITH ORGANIC
    PEROXIDES, EXPOSURE TO HEAT, OPEN FLAME, AND PROLONGED STORAGE
    ABOVE 100F.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND
    LOCAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.